Laminate properties

Calculated properties for our standard laminates. Start from one of these in the designer, change any ply, and it recalculates for your exact part.

Classical laminate theory, wet layup, vacuum bagged. Not test data and not design allowables. No knockdowns for voids, heat or moisture. How these are calculated

Solid carbon plate

Woven twill: 0° is a 0/90 ply, 45° is a ±45 ply. Quasi-isotropic, so X and Y are the same.

LaminateThickness
mm
Weight
kg/m²
Bending stiffness D
N·m
E / G
GPa
Same bending stiffness as
6061 aluminum plate
Thin plate8 plies carbon twill
[(0/45)2]s
1.980.078 in2.7727.436 / 13.51.7 mm, 39% lighter
Standard plate12 plies carbon twill
[(0/45)3]s
2.960.117 in4.1687.936 / 13.52.5 mm, 38% lighter
Heavy plate16 plies carbon twill
[(0/45)4]s
3.950.156 in5.5520336 / 13.53.3 mm, 37% lighter

Foam-core sandwich

Skins are all 0° twill (0/90), so X and Y are the same. E and G are for one skin. D is for the whole panel and leaves out core shear deflection.

LaminateThickness
mm
Weight
kg/m²
Bending stiffness D
N·m
Skin E / G
GPa
Same bending stiffness as
6061 aluminum plate
Standard3 plies carbon twill each side
12.7 mm SAN foam, 80 kg/m³
14.200.559 in3.463,44051.2 / 2.568.4 mm, 85% lighter
Stiff3 plies carbon twill each side
19.05 mm SAN foam, 80 kg/m³
20.500.807 in4.007,47051.2 / 2.5610.9 mm, 86% lighter
Heavy duty4 plies carbon twill each side
19.05 mm SAN foam, 130 kg/m³
21.000.827 in5.7210,20051.2 / 2.5612.1 mm, 83% lighter
Glass, stiff3 plies E-glass each side
19.05 mm SAN foam, 80 kg/m³
20.600.811 in4.652,79017.8 / 2.737.9 mm, 78% lighter

Also available: glass plate (8 plies E-glass), light sandwich (2 plies carbon, 9.5 mm foam) and standard glass sandwich (12.7 mm foam). The designer shows their values.

First-ply failure

Force per unit width at which the first ply is predicted to fail, in N/mm. In-plane load on a uniform, uncut section. Compression is the lower of the X and Y values. No safety factor.

Solid plateTensionCompressionIn-plane shear
Thin plate513474356
Standard plate769710534
Heavy plate1,030947713
Sandwich (skin)TensionCompressionIn-plane shearCore shear capacity
Standard55332095.712.9
Stiff55532298.819
Heavy duty74668913935.1
Glass, stiff16124610319

Using the numbers

D is bending stiffness per unit width (EI per metre of width). For a strip simply supported on two edges under uniform pressure:

δ = 5 p L⁴ / (384 D)  with p in Pa, L in m, D in N·m, δ in m.

Example: standard sandwich (D = 3,440 N·m), 500 mm span, 1 kPa gives 0.24 mm from bending. A sandwich also deflects in core shear, which adds to this, most on short spans. Check holes, inserts, edges and buckling for your own loads.

The sandwich beam calculator adds core shear deflection and checks skin and core stress for your span and load. Enter the core properties from your own data.

Fabrics

Nominal cured ply thickness in mm, by process, from our manufacturing partner. Actual thickness varies with the layup. Prepreg plies are carbon with a low-temperature-cure epoxy.

FabricWet layupInfusionPrepreg
Carbon fiber 3K 2×2 twill, 200 g/m²0.2470.240—
Carbon fiber 12K 2×2 twill, heavy, ~670 g/m²0.8270.804—
Carbon fiber stitched double bias ±45, 400 g/m²0.4450.404—
Carbon fiber stitched biaxial 0/90, ~380 g/m²0.4200.382—
Carbon fiber unidirectional, 150 g/m²0.1670.151—
Carbon fiber unidirectional, 300 g/m²0.3330.303—
E-glass woven cloth (7781 style), 300 g/m²0.2630.236—
E-glass stitched double bias ±45, ~600 g/m²0.5250.472—
Carbon fiber prepreg, 2×2 twill, 200 g/m² fiber——0.220
Carbon fiber prepreg, double bias ±45, 400 g/m² fiber——0.436
Carbon fiber prepreg, unidirectional, 150 g/m² fiber——0.151
Carbon fiber prepreg, unidirectional, 300 g/m² fiber——0.303

Cores

How these are calculated

Values as of November 23, 2026.